Deck wi 1 2 0 bolts steel deck standing seam mtl.
Roof wall detail steel.
Purlins girts and roof deck the substructure to which the metal panels are fastened must be properly spaced and sufficiently thick to provide a roof or wall system able to meet required design loads.
From modern to traditional designs our metal building trim details and interlocking exterior panel systems eliminate thermal gaps.
Roof area divider curb type.
Use of continuous single piece solid metal flashing vs.
Step flashing at roof wall abutments steep slope roofs.
Wall with self terminating parapro paraflex 531 liquid flashing.
Also see flashing roof wall details for more details about proper exterior wall flashing specifications.
Wall flashing with coated metal edge.
Bending and bowing aluminum and steel roofing and siding sheets are rollformed from hardened tempered metal for maximum strength.
Our photo shows the bottom end of a single piece of damaged sloped roof wall flashing.
Detail for attachment to metal panel siding or fascia.
If a sheet must be bent a gentle 90 degree bend is the maximum recom mended.
Exterior wall parapet rafters prep.
Roof to wall flashing is bent at a 110.
Metal should not be re bent once it has been formed nor should it be folded back on itself.
Here is an attempt though maybe not a very good one to make the roof flashing serve also as a through the wall flashing with a tile roof.
Brick veneer cmu backup rigid insul.
Block bolted to mtl.
Single wall steel vent pipe treated wd.
Pre finished roof and wall panels.
To wall sloped roof no overhang ledger support.
It is designed to cover and protect roof to wall intersections from water infiltration.
Product overview the gibraltar roof to wall flashing is made from trusted 28 gauge galvanized steel.
A 2 nominal lumber thickness provides the maximum pullout values for both screws and nails when the fasteners penetrate a.
Heat welded walkway installation.
Roof detail pitched roof to high wall 01 030 0751.
Cad details document name pdf dwg download all cad construction details 37 1 mb 3 4 mb mc01 identification of roof areas 694 kb 167 kb mc01a single layer underlayment 678 kb 302 kb mc01b double layer underlayment 711 kb 322 kb mc02 vent pipe flashing 626 kb 349 kb mc03 valley.
Wall base termination detail.
We provide pre engineered interlocking wall and roof panels that offer unlimited design themes and superior thermal efficiency.
W taped joints veneer ties.
Paraguard expansion joint roof to wall with parasolo flashing.